12/24V signal interface solutions | Australian engineering
Sensor working. Instrument not reading?
A working sensor can produce a signal that a replacement gauge, controller or tracking system cannot read. Bolec helps identify the mismatch and select a practical interface solution.
01 / Variable AC input
The pickup waveform changes with operating speed. A healthy signal may still need conditioning.
02 / Conditioned output
DB1-128 provides a square-wave output for compatible equipment, with optional fixed frequency division.
03 / Match the application
Confirm the instrument’s input requirements and check performance from low to high operating speed.
START WITH THE SYMPTOM
Three common signal problems
The sensor may be healthy. The problem can be the voltage level, the waveform, the pulse rate, or what the receiving equipment expects.
No reading from a working sensor
A magnetic pickup or alternator AC signal may need conditioning before an electronic gauge can use it.
The instrument reads too high or too low
A changed sensor, instrument, engine or gearing may require frequency division or an adjustable ratio.
Legacy equipment needs special outputs
Some applications require separate signals, a 180-degree phase relationship or duty-cycle adjustment.
CASE STUDIES & APPLICATION NOTES
Real situations. Practical engineering.
The bus moves, but onboard equipment misses the speed pulses.
A transport fleet used DB1-128 units to interface existing vehicle speed signals with additional onboard electronics. Some vehicles subsequently showed inconsistent low-speed detection, requiring closer investigation of their input waveforms and frequency response.
A customer needs 411.100-style functions in a practical wiring format.
Bolec previously discussed a 411.100-style interface with alternative housing and pigtail wiring. The required output functions and connection details were key to selecting the correct product, rather than substituting a simpler converter on part number alone.
The speedometer shows 80 km/h when the verified speed is 70 km/h.
The required frequency ratio would be 70 / 80 = 0.875. DB1-128 cannot create this fine correction: it only provides fixed division by 1, 2, 4, 8, 16, 32, 64 or 128. ERB205 is a better product to evaluate when the electrical signal is compatible.
SELECT BY APPLICATION
Three different tools for three different jobs.

Condition and divide
Converts compatible AC/pulse inputs into one supply-level square-wave output. Fixed division from ÷1 to ÷128.
Specialised multi-output interface
Three signal outputs, including 180° phase-opposed signals and a duty-cycle-adjustable output. Fixed division up to ÷16.

Adjust the frequency ratio
For compatible speedometer and tachometer systems needing fine ratio correction rather than a fixed power-of-two divider.
Module selection depends on actual input/output requirements. Bolec recommends qualified installation and confirmation of performance across the full operating range.
HOW WE HELP
Bring the problem, not just a part number.
01
Describe
What equipment is fitted and what does not work?
02
Measure
Record waveform, peak-to-peak voltage and frequency range.
03
Select
Evaluate a module or ask about a tailored approach.
04
Verify
Test the actual equipment at low and high operating speeds.
TECHNICAL ENQUIRIES | MELBOURNE, AUSTRALIA
Before replacing the whole system, ask us about the signal.
Send the vehicle/engine model, sensor and instrument part numbers, supply voltage, signal measurements, wiring information and expected quantities. We can help identify the next engineering step.
Helpful details to include
✓ Equipment make and model
✓ 12/24 VDC supply
✓ Input waveform and frequency
✓ Actual vs expected reading
✓ Photos / wiring diagrams