Australian Made Since 1978 Quality Reliability Local Support
  • Home
  • /
  • Shop
  • /
  • Bolec BEM302 Basic Engine Protection – Panel Watchdog panel

Bolec BEM302 Basic Engine Protection – Panel Watchdog panel

$1,028.00

Add 1.5m Breakout Harness (+$150)

Adds a 1.5m breakout harness to your kit

Add WL601P Probe

WL601P Water Level Probe

Product price:$1,028.00
Total options:
Order total:

BEM302 Engine Protection & Automatic Shutdown Panel — monitors six
engine or machine fault inputs, delays protection during starting, then provides
audible / visual warning and automatic shutdown when a valid fault is detected.

6 monitored inputs
Startup delay
Automatic shutdown
Fault Recall — up to 6 events
12VDC / 24V available
IP56 enclosure

Suitable for trucks, buses, boats, agricultural machinery and stationary engines.
A practical Murphy 09PWP12V09 / D3 Watchdog alternative for suitable
applications after wiring, voltage, sensor and shutdown requirements are verified.

BOLEC Product Specification Selector

Search by keyword, thread size or SKU, or choose a filter. Compare up to three products.

Compatibility note

This selector narrows products by stated specifications only and does not confirm direct compatibility. Water gauge: 291.4–22.4 Ω; water senders: 291.5–22.4 Ω. Oil temperature gauge: 316–19 Ω; oil temperature senders: 361–19 Ω. The 0–5 bar oil pressure gauge and 0–10 bar pressure sender use different pressure ranges. Confirm the complete calibration and installation requirements before ordering.

Try:
No products shown yet.Choose a filter above or enter a keyword / SKU to see matching products.

Compare selected products

Similar thread sizes, resistance values or ranges do not confirm compatibility.

BOLEC Engine protection and automatic shutdown panel
Bolec BEM302 engine protection and automatic shutdown panel

Six-input engine watchdog

BEM302

Basic Engine Protection / Watchdog Panel

  • Six monitored fault inputs
  • Startup delay
  • Automatic shutdown
  • Audible and visual fault warning
  • Fault Recall — up to six events

bolec.com.au | sales@bolec.com.au | 0480 312 400

BEM302 overview

Engine protection, automatic shutdown and fault history in one panel

The BEM302 is a compact electronic engine watchdog panel for trucks, buses, boats, agricultural machinery and stationary engines. It monitors six connected fault inputs, allows the engine to stabilise during starting, then provides warning and automatic shutdown when a valid fault is detected.

  • Monitors six engine or machine fault inputs
  • Startup delay prevents nuisance shutdown during cranking
  • Audible and visual fault warning
  • Automatic engine shutdown output
  • Fault Recall stores up to six fault events
  • 12VDC standard; 24V version available
A4 product summary — print or save as PDF. Print this page
Operating sequence

How the BEM302 protects the engine

One simple sequence explains what happens from starting through to shutdown and diagnosis.
  1. Engine startsThe machine uses its normal starting controls.
  2. Startup delayOil pressure and charging conditions are allowed to stabilise.
  3. Monitoring activeThe six connected protection inputs are watched continuously.
  4. Fault detectedA connected switch changes state because an abnormal condition is present.
  5. Alarm and shutdownThe warning and shutdown outputs are activated.
  6. Fault retainedFault history can be recalled for troubleshooting.
Installation note:The final engine stop method depends on the fuel solenoid, stop circuit, connected switches and wiring. Installation and commissioning should be completed by a suitably qualified technician.
Protection inputs

What the BEM302 monitors

All six published protection functions are kept together in one table so they are easy to find.
Low oil pressureMonitors the connected oil-pressure switch and initiates shutdown when a valid low-pressure fault is detected after startup.
High engine temperatureUses the connected temperature switch to protect the engine when the configured high-temperature condition is reached.
Alternator / belt failureMonitors the charging or belt-failure input so loss of alternator operation can be identified.
Loss of coolantCan monitor a compatible coolant-level circuit to detect coolant loss before severe overheating occurs.
Configurable spare input 1Can be allocated to an additional engine or machine protection condition.
Spare input 2 / pump loss of primePublished with pump loss of prime as the default application and may suit another configured fault function.
Fault Recall

See the stored fault history after the engine has stopped

The BEM302 does more than indicate that a shutdown occurred. Its published Fault Recall function allows up to six fault events to be recalled, helping operators and technicians investigate recurring or intermittent shutdowns.
Up to six fault events
  • Review fault history after shutdown
  • Assist diagnosis of intermittent problems
  • Confirm the protection inputs during commissioning
Murphy 09PWP12V09 / D3 Watchdog comparison

BEM302 vs Murphy 09PWP12V09 engine protection panel

The BEM302 can be a practical Murphy Watchdog alternative for suitable applications, but the two products use different panel formats and must be selected by function, wiring and required instruments.
Selection pointBolec BEM302Murphy 09PWP12V09 / D3 Watchdog
Panel formatElectronic six-input engine protection panelGauge-based weatherproof engine protection panel
Monitored functionsOil pressure, engine temperature, alternator / belt failure, coolant loss and two spare inputsOil pressure, engine temperature and water pressure Swichgage functions
Automatic shutdownYes — electronic shutdown sequenceYes — Murphy 518 shutdown relay
TimingStartup delay for protection during crankingPublished with a run timer up to 100 hours
Fault historyFault Recall of up to six eventsNo equivalent six-fault memory is listed on the current Bolec Murphy product page
Tachometer / hour meterNot listed as a standard BEM302 functionPublished with 0–3000 RPM tacho / hour meter
Replacement guidanceDo not assume a direct or pin-for-pin replacement. Verify supply voltage, sensor and switch types, shutdown logic, output load, panel dimensions and required instruments before replacing a Murphy panel with a BEM302.

Murphy, D3 Watchdog and Swichgage names are used for product identification and application comparison. Specifications can vary by panel configuration.

Published product data

BEM302 specifications

Model / SKUBEM302
ApplicationsTrucks, buses, boats, agricultural machinery and stationary engines
Supply12VDC; 24V version available
Enclosure ratingIP56
Monitored inputs6
Published outputs2
Output relay30A at 12VDC
Fault historyFault Recall of up to six fault events
Published dimensions280 × 190 × 130mm

Available product options

  • 1.5m breakout harness
  • WL601P coolant-level probe option
Available options are selected in the purchase area above the product description.

Commissioning checks

  • Confirm each fault input and switch polarity.
  • Confirm shutdown output operation and connected load.
  • Test the startup delay and each shutdown condition.
  • Verify that fault history can be recalled after shutdown.
Watch the Bolec engine protection panel video

The controlled BEM302 instruction manual and the markings on the supplied product take precedence.

Frequently asked questions

BEM302 selection and replacement questions

Is the BEM302 a direct replacement for a Murphy 09PWP12V09 panel?
No direct or pin-for-pin replacement is claimed. The BEM302 can be a practical alternative where its six electronic fault inputs, shutdown logic and output arrangement suit the application. Murphy gauge functions, wiring and panel instruments must be checked individually.
What does Fault Recall store?
The published Fault Recall function allows up to six fault events to be recalled for troubleshooting after a shutdown.
Why is there a startup delay?
During cranking, oil pressure and charging conditions may not yet be normal. The delay prevents these expected startup conditions from creating an immediate false shutdown.
Does the BEM302 stop the engine automatically?
Yes. After the startup delay, a valid monitored fault activates the warning and shutdown sequence. The final stop method depends on the connected engine shutdown circuit.
Documents and support

BEM302 instruction manual and application assistance

  View BEM302 Instruction Manual Installation, operation and controlled product information.   Technical and replacement support Ask about sensors, wiring, shutdown logic, output loading or Murphy Watchdog suitability.  

Bolec Electronics


Founded in 1978, Bolec Electronics has developed a portfolio of over 80 products and a reputation that survive and thrive in some of Australia's harshest environments. Bolec Electronics is the OE supplier to some of the world's largest truck and engine manufactures.

Premium quality

Easy to install

lightweight

Designed and made in Australia

>